Home > Products > Centrifuges > Magnus 21/21R

MAGNUS 21/21R

Description of Magnus 21/21R

The Magnus 21 centrifuge and its refrigerated version,Magnus 21 R , can process a volume up to 2.6 liters on a underfloor device, ofering a complete solution in the preparation of samples by centrifugation on research clinics, biotechnology, industrial labs.

The large selection of rotors and adapters the induction motor,maintenance free an easy to use software,which controls centrifugation values, and graphics shown on TFT touch screen, provides to the user of an ally in routine work.

Orto Alresa in its commitment to innovation offers the control of the braking stage in a wide spectrum variable by the operator in a range of between 5 and 180 seconds, depeding of the rotor, thus achieving the reduction in braking time suitable for each type of sample.


inf Download pdf

Features

  • Induction motor, maintenance free.
  • Controlled by microprocessor.
  • Minimum acceleration time.
  • Noise level < 60 dB.
  • Automatic rotor recognition:shown on screen max. R.P.M., max. R.C.F. and max. capacity, avoiding exceed the max speed.
  • Temperature regulation form -20 to 40ºC (Magnus 21 R).
  • Lid open programmable: automatically at the end of the run or pressing lid button.
  • Temperature selectable on ºC/F.
  • Short cycle speed selectable.

Easy to use

  • TFT touch colorful.
  • RPM selection on steps of 100, of R.P. M. on 10 xg, time on 1 minutes to 99 and hold position.
  • 16 memories.
  • Countdown at set R.P.M./R.C.F. allowing reproducibles results.
  • Screen show the values or graphics of set and updated.
  • Switches for open lid, start stop,enter, and exit.
  • Shown at any time the centrifuge and accessories state.
  • Breaking ramps from 5 to 180 seconds.
  • Motorized lid latch system .
  • Pre-cooling program with temperature selectable (Magnus 21R).
  • Along centrifugation it shown a graphic wheel wich inform us about the centrifugation stage from distances >3 m.
  • Rotors and adapters list on memory with its max RPM/RCF and centrifugation values do not require introduce any parameter.

Safety features

  • Initial checking of the device and its accessories
  • Chamber of centriugation in stainless steel, guard ring around chamber.
  • Lid dropping protection.
  • Unbalance cut off.
  • Double emergency lid release.
  • It can not run with the lid open, neither lid can be open until the rotor stops.
  • Air cooled (Magnus 21).
  • Lids for buckets availables.
  • Control by R.C.F.(xg): permits reproduce protocols designed in other centrifugues, avoiding the interferences produced by R.P.M.
  • Temperature probe inside the chamber of centrifugation, gas R 404A (CFC free, Magnus 20 R).
Community directives:73/23/CEE 89/336/CEE. Standards 61010-2, 61010- 2-020, 61000-3, 61000-4 , 55011.

Versions

codevoltajefrecuencyloadweightdimensions
CE 130110-120 V50-60 Hz600 W113Kg54x65x93 (h) cm
CE 129220-240 V50-60 Hz1200 W105 Kg54x65x93 (h) cm
CE 131110-120 V50-60 Hz1200 W105 Kg54x65x93 (h) cm
CE 128220-240 V50-60 Hz600 W113 Kg54x65x93 (h) cm
-
Accessories
-
  Capacity
  R.P.M.
  Radio mm.
  R.C.F
  Min Temp at Max speed
  ADAPTERS  Dm. (mm)
  500  90x120
  250  60x129
  100  48x95
  80hs  38x112
  80  44x100
  50hs  29x108
  50  35x100
  50falcon  29x117
  30hs  25x98
  30  25x98
  15  16x100
  15falcon  17x122
  15vacuum  16x132
  10vacuum  16x107
  10hs  16x80
  10  13x100
  7/10vacuum  13x107
  5vacuum  13x82
  5  13x75
  10x10  10x100
  1,5x75capillaries  1,5x75
  1,5-2microtubes  11x39
  0,5-0,6microtubes  8x30
  0,2-0,4microtubes  6x45
  128x86x15  128x86x15

RT 191 (1)
id
swing out
RT 192
id
swing out
RT 195
id
swing out
RT 196
id
angel fixed 35º
RT 197
id
angel fixed 45º
RT 198
id
angel fixed 45º
RT 199
id
angel fixed 30º
RT 201 (2)
id
swing out
RT 202
id
swing out
RT 206
id
angel fixed 45º
4x650 ml.4x250 ml.104x5ml.8x30 ml.8x50 ml.4x100 ml.4x250 ml.4 bolsas sangre12 p. microtiter30x1,5-2 ml.
35004000350070005000520047003500350013300
19220218510214913815320418296
26303613253455884165417237792794249318985
-4-2-4-3-4-4-4-3-4-4
TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF
4RE 310 -- -- -- -- -- -- -- -- --
4RE 330 4- -- -- -- -- 4- -- -- --
4RE 409 4RE 327 -- -- -- 4- 4RE 327 4RE 310 -- --
-- -- -- -- -- -- -- 4RE 409 -- --
8RE 352 4RE 422 -- -- -- 4RE 338 4RE 422 4RE 330 -- --
-- -- -- -- -- -- -- 8RE 352 -- --
16RE 317 4RE 334 -- -- 8- 4RE 335 4RE 334 16RE 317 -- --
16RE 318 4RE 340 -- -- 8RE 375 4RE 341 4RE 340 16RE 318 -- --
-- -- -- -- -- -- -- 24RE 322 -- --
24RE 322 12RE 312 -- 8- 8RE 370 4RE 332 12RE 312 72RE 348 -- --
72RE 348 28RE 376 -- 8RE 368 8RE 369 16RE 316 28RE 376 52RE 347 -- --
52RE 347 20RE 321 -- 8RE 368 8RE 369 4RE 339 20RE 321 -- -- --
-- 28RE 376 -- 8RE 368 8RE 369 -- 28RE 376 -- -- --
72RE 348 28RE 376 -- 8RE 368 8RE 369 16RE 316 28RE 376 72RE 349 -- --
-- -- -- -- -- -- -- 84RE 354 -- --
84RE 354 40RE 343 104RE 309 8RE 372 24RE 366 20RE 320 40RE 343 72RE 348 -- --
72RE 349 28RE 324 104RE 309 8RE 372 8RE 373 20RE 320 28RE 324 84RE 354 -- --
72RE 349 28RE 324 104RE 309 8RE 372 8RE 373 20RE 320 28RE 324 144RE 315 -- --
84RE 354 40RE 343 104RE 309 8RE 372 24RE 366 20RE 320 40RE 343 72RE 349 -- --
144RE 315 52RE 346 -- 8RE 374 24RE 367 36RE 326 52RE 346 -- -- --
-- -- -- -- -- -- -- 12RE 307 12- --
72RE 426 24RE 440 -- -- -- 20RE 408 24RE 440 72RE 426 -- 30-
-- -- -- -- -- -- -- -- -- 30RE 428
-- -- -- -- -- -- -- -- -- 30RE 427
12RE 307 -- -- -- -- -- -- -- -- --
(1) availables lids for that buckets (RE 356)
(2) This rotor can fit adapters for blood bags (RE 308)/ availables lids for that buckets (RE 356)