MAGNUS 21/21R
Description of Magnus 21/21R
The Magnus 21 centrifuge and its refrigerated version,Magnus 21 R , can process a volume up to 2.6 liters on a underfloor device, ofering a complete solution in the preparation of samples by centrifugation on research clinics, biotechnology, industrial labs.
The large selection of rotors and adapters the induction motor,maintenance free an easy to use software,which controls centrifugation values, and graphics shown on TFT touch screen, provides to the user of an ally in routine work.
Orto Alresa in its commitment to innovation offers the control of the braking stage in a wide spectrum variable by the operator in a range of between 5 and 180 seconds, depeding of the rotor, thus achieving the reduction in braking time suitable for each type of sample.
Download pdf
The large selection of rotors and adapters the induction motor,maintenance free an easy to use software,which controls centrifugation values, and graphics shown on TFT touch screen, provides to the user of an ally in routine work.
Orto Alresa in its commitment to innovation offers the control of the braking stage in a wide spectrum variable by the operator in a range of between 5 and 180 seconds, depeding of the rotor, thus achieving the reduction in braking time suitable for each type of sample.
Download pdfFeatures
- Induction motor, maintenance free.
- Controlled by microprocessor.
- Minimum acceleration time.
- Noise level < 60 dB.
- Automatic rotor recognition:shown on screen max. R.P.M., max. R.C.F. and max. capacity, avoiding exceed the max speed.
- Temperature regulation form -20 to 40ºC (Magnus 21 R).
- Lid open programmable: automatically at the end of the run or pressing lid button.
- Temperature selectable on ºC/F.
- Short cycle speed selectable.
Easy to use
- TFT touch colorful.
- RPM selection on steps of 100, of R.P. M. on 10 xg, time on 1 minutes to 99 and hold position.
- 16 memories.
- Countdown at set R.P.M./R.C.F. allowing reproducibles results.
- Screen show the values or graphics of set and updated.
- Switches for open lid, start stop,enter, and exit.
- Shown at any time the centrifuge and accessories state.
- Breaking ramps from 5 to 180 seconds.
- Motorized lid latch system .
- Pre-cooling program with temperature selectable (Magnus 21R).
- Along centrifugation it shown a graphic wheel wich inform us about the centrifugation stage from distances >3 m.
- Rotors and adapters list on memory with its max RPM/RCF and centrifugation values do not require introduce any parameter.
Safety features
- Initial checking of the device and its accessories
- Chamber of centriugation in stainless steel, guard ring around chamber.
- Lid dropping protection.
- Unbalance cut off.
- Double emergency lid release.
- It can not run with the lid open, neither lid can be open until the rotor stops.
- Air cooled (Magnus 21).
- Lids for buckets availables.
- Control by R.C.F.(xg): permits reproduce protocols designed in other centrifugues, avoiding the interferences produced by R.P.M.
- Temperature probe inside the chamber of centrifugation, gas R 404A (CFC free, Magnus 20 R).
Versions
| code | voltaje | frecuency | load | weight | dimensions |
| CE 130 | 110-120 V | 50-60 Hz | 600 W | 113Kg | 54x65x93 (h) cm |
| CE 129 | 220-240 V | 50-60 Hz | 1200 W | 105 Kg | 54x65x93 (h) cm |
| CE 131 | 110-120 V | 50-60 Hz | 1200 W | 105 Kg | 54x65x93 (h) cm |
| CE 128 | 220-240 V | 50-60 Hz | 600 W | 113 Kg | 54x65x93 (h) cm |
Accessories
| - | |
| Capacity | |
| R.P.M. | |
| Radio mm. | |
| R.C.F | |
| Min Temp at Max speed | |
| ADAPTERS | Dm. (mm) |
| 500 | 90x120 |
| 250 | 60x129 |
| 100 | 48x95 |
| 80hs | 38x112 |
| 80 | 44x100 |
| 50hs | 29x108 |
| 50 | 35x100 |
| 50falcon | 29x117 |
| 30hs | 25x98 |
| 30 | 25x98 |
| 15 | 16x100 |
| 15falcon | 17x122 |
| 15vacuum | 16x132 |
| 10vacuum | 16x107 |
| 10hs | 16x80 |
| 10 | 13x100 |
| 7/10vacuum | 13x107 |
| 5vacuum | 13x82 |
| 5 | 13x75 |
| 10x10 | 10x100 |
| 1,5x75capillaries | 1,5x75 |
| 1,5-2microtubes | 11x39 |
| 0,5-0,6microtubes | 8x30 |
| 0,2-0,4microtubes | 6x45 |
| 128x86x15 | 128x86x15 |
RT 191 (1)![]() swing out | RT 192![]() swing out | RT 195![]() swing out | RT 196![]() angel fixed 35º | RT 197![]() angel fixed 45º | RT 198![]() angel fixed 45º | RT 199![]() angel fixed 30º | RT 201 (2)![]() swing out | RT 202![]() swing out | RT 206![]() angel fixed 45º | ||||||||||
| 4x650 ml. | 4x250 ml. | 104x5ml. | 8x30 ml. | 8x50 ml. | 4x100 ml. | 4x250 ml. | 4 bolsas sangre | 12 p. microtiter | 30x1,5-2 ml. | ||||||||||
| 3500 | 4000 | 3500 | 7000 | 5000 | 5200 | 4700 | 3500 | 3500 | 13300 | ||||||||||
| 192 | 202 | 185 | 102 | 149 | 138 | 153 | 204 | 182 | 96 | ||||||||||
| 2630 | 3613 | 2534 | 5588 | 4165 | 4172 | 3779 | 2794 | 2493 | 18985 | ||||||||||
| -4 | -2 | -4 | -3 | -4 | -4 | -4 | -3 | -4 | -4 | ||||||||||
| TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF |
| 4 | RE 310 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 4 | RE 330 | 4 | - | - | - | - | - | - | - | - | - | 4 | - | - | - | - | - | - | - |
| 4 | RE 409 | 4 | RE 327 | - | - | - | - | - | - | 4 | - | 4 | RE 327 | 4 | RE 310 | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 4 | RE 409 | - | - | - | - |
| 8 | RE 352 | 4 | RE 422 | - | - | - | - | - | - | 4 | RE 338 | 4 | RE 422 | 4 | RE 330 | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8 | RE 352 | - | - | - | - |
| 16 | RE 317 | 4 | RE 334 | - | - | - | - | 8 | - | 4 | RE 335 | 4 | RE 334 | 16 | RE 317 | - | - | - | - |
| 16 | RE 318 | 4 | RE 340 | - | - | - | - | 8 | RE 375 | 4 | RE 341 | 4 | RE 340 | 16 | RE 318 | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 24 | RE 322 | - | - | - | - |
| 24 | RE 322 | 12 | RE 312 | - | - | 8 | - | 8 | RE 370 | 4 | RE 332 | 12 | RE 312 | 72 | RE 348 | - | - | - | - |
| 72 | RE 348 | 28 | RE 376 | - | - | 8 | RE 368 | 8 | RE 369 | 16 | RE 316 | 28 | RE 376 | 52 | RE 347 | - | - | - | - |
| 52 | RE 347 | 20 | RE 321 | - | - | 8 | RE 368 | 8 | RE 369 | 4 | RE 339 | 20 | RE 321 | - | - | - | - | - | - |
| - | - | 28 | RE 376 | - | - | 8 | RE 368 | 8 | RE 369 | - | - | 28 | RE 376 | - | - | - | - | - | - |
| 72 | RE 348 | 28 | RE 376 | - | - | 8 | RE 368 | 8 | RE 369 | 16 | RE 316 | 28 | RE 376 | 72 | RE 349 | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 84 | RE 354 | - | - | - | - |
| 84 | RE 354 | 40 | RE 343 | 104 | RE 309 | 8 | RE 372 | 24 | RE 366 | 20 | RE 320 | 40 | RE 343 | 72 | RE 348 | - | - | - | - |
| 72 | RE 349 | 28 | RE 324 | 104 | RE 309 | 8 | RE 372 | 8 | RE 373 | 20 | RE 320 | 28 | RE 324 | 84 | RE 354 | - | - | - | - |
| 72 | RE 349 | 28 | RE 324 | 104 | RE 309 | 8 | RE 372 | 8 | RE 373 | 20 | RE 320 | 28 | RE 324 | 144 | RE 315 | - | - | - | - |
| 84 | RE 354 | 40 | RE 343 | 104 | RE 309 | 8 | RE 372 | 24 | RE 366 | 20 | RE 320 | 40 | RE 343 | 72 | RE 349 | - | - | - | - |
| 144 | RE 315 | 52 | RE 346 | - | - | 8 | RE 374 | 24 | RE 367 | 36 | RE 326 | 52 | RE 346 | - | - | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 12 | RE 307 | 12 | - | - | - |
| 72 | RE 426 | 24 | RE 440 | - | - | - | - | - | - | 20 | RE 408 | 24 | RE 440 | 72 | RE 426 | - | - | 30 | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 30 | RE 428 |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 30 | RE 427 |
| 12 | RE 307 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
(1) availables lids for that buckets (RE 356)
(2) This rotor can fit adapters for blood bags (RE 308)/ availables lids for that buckets (RE 356)
(2) This rotor can fit adapters for blood bags (RE 308)/ availables lids for that buckets (RE 356)









