DIGTOR 21/21R
Description of Digtor 21/21R
The Digtor 21 centifruge and the refrigerated Digtor 21 R , can process a volume of up to 2.6 liters in the bench top version, offering a complete solution in the preparation of samples to be centrifuged for research labs, clinic, biotechnologic, industrial and hospitals.
The large selection of rotors and adapters to 40 its motor maintenance free, a software which allows the operator to control the centrifugation parameters easily,and the graphics shown on the TFT touch colorful screen provide the user with an easy to handle machine and an ally in the daily tasks.
Orto Alresa in its commitment to innovation offers the control of the braking stage in a wide spectrum variable by the operator in a range of between 5 and 180 seconds depending on the rotor, thus achieving the reduction in braking time suitable for each type of sample.
Download pdf
The large selection of rotors and adapters to 40 its motor maintenance free, a software which allows the operator to control the centrifugation parameters easily,and the graphics shown on the TFT touch colorful screen provide the user with an easy to handle machine and an ally in the daily tasks.
Orto Alresa in its commitment to innovation offers the control of the braking stage in a wide spectrum variable by the operator in a range of between 5 and 180 seconds depending on the rotor, thus achieving the reduction in braking time suitable for each type of sample.
Download pdfFeatures
- Induction motor maintenance free.
- Controlled by microprocessor
- Minimun acceleration time.
- Noise level lower than 60 dB.
- Automatic rotor recognition: Shown on screen max. R.P.M., max. R.C.F. and max. capacity, avoiding exceeding the maximum speed
- Temperature regulation from -20 to 40º C( Digtor 21 R).
- Lid open programmable: automatically at the end of the run or pressing lid button.
- Temperature selectable on ºC/F.
- Short cycle speed selectable.
Easy to use
- TFT screen colorful.
- RPM regulation on steps of 100, R.C.F on 10 xg, time from 1 to 99 minutes and hold position.
- Up to 16 programs on store.
- Countdown start at set RPM /RCF allowing reproducibles results.
- Screen show the values or graphics of set and updated.
- Switches for open the lid, start, stop enter and exit.
- Messages on screen indicating the centrifuge and accessories state.
- Breaking ramps from 5 to 180 seconds.
- Lid latch motorized.
- Pre-cooling program with temperature selectable (Digtor 21R). Its shown along centrifugation a wheel as indicator or cycle stage, just on a sightyou can see from any place of the lab itsstate and non stop your work.
- Rotors and adapters list on memory.
Safety features
- Initial checking of the device and its accessories.
- Centrifugation chamber in stainless steel, guard ring around chamber.
- Lid dropping protection
- Unbalance cutt off.
- Double manual emergency lid release.
- It can not run with the lid open, neither open the lid when rotor runs.
- Air Cooled( Digtor 21).
- Lid for buckets availables.
- Control by R.C.F.(xg): allows reproduce protocols designed in other devices, avoiding the interferences by R.P.M.
- Temperature probe inside the chamber of centrifugation, gas R 404A (libre CFC, 21R).
Versions
| code | voltage | frecuency/td> | load | weight | dimensions |
| CE 112 | 220-240 V | 50-60 Hz | 600 W | 50 Kg | 54x65x39 (h) cm |
| CE 118 | 110-120 V | 50-60 Hz | 600 W | 50 Kg | 54x65x39 (h) cm |
| CE 115 | 220-240 V | 50-60 Hz | 1200 W | 95 Kg | 72x80,5x39 (h) cm |
| CE 121 | 110-120 V | 50-60 Hz | 1200 W | 95 Kg | 72x80,5x39 (h) cm |
Accessories
| - | |
| Capacity | |
| R.P.M. | |
| Radio mm. | |
| R.C.F | |
| Min Temp at Max speed | |
| ADAPTERS | Dm. (mm) |
| 500 | 90x120 |
| 250 | 60x129 |
| 100 | 48x95 |
| 80hs | 38x112 |
| 80 | 44x100 |
| 50hs | 29x108 |
| 50 | 35x100 |
| 50falcon | 29x117 |
| 30hs | 25x98 |
| 30 | 25x98 |
| 15 | 16x100 |
| 15falcon | 17x122 |
| 15vacuum | 16x132 |
| 10vacuum | 16x107 |
| 10hs | 16x80 |
| 10 | 13x100 |
| 7/10vacuum | 13x107 |
| 5vacuum | 13x82 |
| 5 | 13x75 |
| 10x10 | 10x100 |
| 1,5x75capillaries | 1,5x75 |
| 1,5-2microtubes | 11x39 |
| 0,5-0,6microtubes | 8x30 |
| 0,2-0,4microtubes | 6x45 |
| 128x86x15 | 128x86x15 |
RT 191 (1)![]() swing out | RT 192![]() swing out | RT 195![]() swing out | RT 196![]() angel fixed 35º | RT 197![]() angel fixed 45º | RT 198![]() angel fixed 45º | RT 199![]() angel fixed 30º | RT 201 (2)![]() swing out | RT 202![]() swing out | RT 206![]() angel fixed 45º | ||||||||||
| 4x650 ml. | 4x250 ml. | 104x5ml. | 8x30 ml. | 8x50 ml. | 4x100 ml. | 4x250 ml. | 4 bolsas sangre | 12 p. microtiter | 30x1,5-2 ml. | ||||||||||
| 3500 | 4000 | 3500 | 7000 | 5000 | 5200 | 4700 | 3500 | 3500 | 13300 | ||||||||||
| 192 | 202 | 185 | 102 | 149 | 138 | 153 | 204 | 182 | 96 | ||||||||||
| 2630 | 3613 | 2534 | 5588 | 4165 | 4172 | 3779 | 2794 | 2493 | 18985 | ||||||||||
| -4 | -2 | -4 | -3 | -4 | -4 | -4 | -3 | -4 | -4 | ||||||||||
| TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF | TUBES | REF |
| 4 | RE 310 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 4 | RE 330 | 4 | - | - | - | - | - | - | - | - | - | 4 | - | - | - | - | - | - | - |
| 4 | RE 409 | 4 | RE 327 | - | - | - | - | - | - | 4 | - | 4 | RE 327 | 4 | RE 310 | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 4 | RE 330 | - | - | - | - |
| 8 | RE 352 | 4 | RE 422 | - | - | - | - | - | - | 4 | RE 338 | 4 | RE 422 | 4 | RE 409 | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8 | RE 352 | - | - | - | - |
| 16 | RE 317 | 4 | RE 334 | - | - | - | - | 8 | RE 374 | 4 | RE 335 | 4 | RE 334 | 16 | RE 317 | - | - | - | - |
| 16 | RE 318 | 4 | RE 340 | - | - | - | - | 8 | RE 375 | 4 | RE 341 | 4 | RE 340 | 16 | RE 318 | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 24 | RE 322 | - | - | - | - |
| 24 | RE 322 | 12 | RE 312 | - | - | 8 | - | 8 | RE 370 | 4 | RE 332 | 12 | RE 312 | 72 | RE 348 | - | - | - | - |
| 72 | RE 348 | 28 | RE 376 | - | - | 8 | RE 368 | 8 | RE 369 | 16 | RE 316 | 28 | RE 376 | 52 | RE 347 | - | - | - | - |
| 52 | RE 347 | 20 | RE 321 | - | - | 8 | RE 368 | 8 | RE 369 | 4 | RE 339 | 20 | RE 321 | - | - | - | - | - | - |
| - | - | 28 | RE 376 | - | - | 8 | RE 368 | 8 | RE 369 | - | - | 28 | RE 376 | - | - | - | - | - | - |
| 72 | RE 348 | 28 | RE 376 | - | - | 8 | RE 368 | 8 | RE 369 | 16 | RE 316 | 28 | RE 376 | 72 | RE 349 | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 84 | RE 354 | - | - | - | - |
| 84 | RE 354 | 40 | RE 343 | 104 | RE 309 | 8 | RE 372 | 24 | RE 366 | 20 | RE 320 | 40 | RE 343 | 72 | RE 348 | - | - | - | - |
| 72 | RE 349 | 28 | RE 324 | 104 | RE 309 | 8 | RE 372 | 8 | RE 373 | 20 | RE 320 | 28 | RE 324 | 84 | RE 354 | - | - | - | - |
| 72 | RE 349 | 28 | RE 324 | 104 | RE 388 | 8 | RE 372 | 8 | RE 373 | 20 | RE 320 | 28 | RE 324 | 144 | RE 315 | - | - | - | - |
| 84 | RE 354 | 40 | RE 343 | 104 | RE 388 | 8 | RE 372 | 24 | RE 366 | 20 | RE 320 | 40 | RE 343 | 72 | RE 349 | - | - | - | - |
| 144 | RE 315 | 52 | RE 346 | - | - | 8 | RE 374 | 24 | RE 367 | 36 | RE 326 | 52 | RE 346 | - | - | - | - | - | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | 12 | RE 307 | 12 | - | - | - |
| 72 | RE 426 | 24 | RE 440 | - | - | - | - | - | - | 20 | RE 408 | 24 | RE 440 | 72 | RE 426 | - | - | 30 | - |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 30 | RE 428 |
| - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 30 | RE 427 |
| 12 | RE 307 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
(1) availables lids for that buckets (RE 356)
(2) This rotor can fit adapters for blood bags (RE 308)/ availables lids for that buckets (RE 356)