Home > Products > Centrifuges > Digicen 21/21R

DIGICEN 21/21R

Description of Digicen 21/21R

The benchtop centrifuge Digicen 21 and its refrigerated version Digicen 20R,have met with great acceptance due to the wide range of accessories, which allow them to have multiple applications.

The maintenance free induction motor makes it suitable for intensive usage and allows centrifuging at low speed range with 100 ml tubes with screw caps , for the extraction of blood, microplates and cell culture as well as at high speed allowing it to reach up to 24,959 x g with microtubes and up to 9,146 x g with 50 ml .

The LCD screen shows in graphic form actual time, R.P.M.and FCR. The automatic identification of the rotor allows showing of the maximum values of the centrifugation parameters permitting selection of up to 175 different braking ramps.


inf Download pdf

Features

  • Backlit LCD screen.
  • Allow control RPM on steps of 100 RPM, FCR in steps od 10 x g, time in minute steps from 1 to 99 and hold position , breaking regulation selectable from 5 to 180 ( rotor dependent and temperature from -20 to 40ºC, (only Digicen 21 R) in steps of 1 ºC.
  • 16 memories
  • Countdown start at set speed or from 0.
  • Values or graphics shown on screen.
  • Buttons for open lid de start, stop, intro and exit.
  • Informs at any time about the centrifuge state, and centrifugation stage.
  • Lid open programmable: automatically at the end of the run or pressing lid button.
  • Acceleration selectable soft and fast.

Easy to use

  • Induction motor, maintenance free.
  • Controlled by microprocessor.
  • Minimum acceleration time.
  • Noise level< 60 Db.
  • Automatic rotor recognition.
  • Lid latch motorized.
  • Pre-cooling program with temperature selectable (Digicen 21R).

Safety features

  • Intitial checking and follow up of device and accessories.
  • Centrifugugation chamber in stainless steel.
  • Lid dropping protection.
  • Double manual emergency release.
  • Unbalance cutt off.
  • Rotor does not run when lid is open and lid can not be open until rotor stop.
  • Temperature probe inside the chamber of centrifugation, CFC free (R 134 A) (only Digicen 21 R).
  • Guard ring around chamber of centrifugation.
  • Air cooled( Digicen 21).
Community directives:73/23/CEE 89/336/CEE.Standards 61010-2, 61010- 2-020, 61000-3, 61000-4 & 55011.

Versions

codevoltagefrecuencyloadweightdimensions
CE 110220-240 V50-60 Hz280 W36 Kg41x53x32 (h) cm
CE 116110-120 V50-60 Hz280 W36 Kg41x53x32 (h) cm
CE 113220-240 V50-60 Hz700 W67 Kg59x68x32 (h) cm
CE 119110-120 V50-60 Hz700 W67 Kg59x68x32 (h) cm
-
Accessories
-
  Capacity
  R.P.M.
  Radio mm.
  R.C.F
  Min Temp at Max speed
  ADAPTERS  Dm. (mm)
  100  48x95
  80hs  38x112
  80  44x100
  50hs  29x108
  50  35x100
  50falcon  29x117
  30hs  25x98
  30  25x98
  15  16x100
  15falcon  17x122
  10vacuum  16x107
  10hs  16x80
  10  13x100
  7/10vacuum  13x107
  5vacuum  13x82
  5  13x75
  1,5x75capillaries  1,5x75
  1,5-2microtubes  11x39
  0,5-0,6microtubes  8x30
  0,2-0,4microtubes  6x45
  128x86x15  128x86x15
  128x86x21  128x86x21
  128x86x45  128x86x45
  128x86x22  

RT 106
id
angel fixed 35º
RT 108
id
angel fixed 35º
RT 110
id
angel fixed 35º
RT 121 (3)
id
angel fixed 45º
RT 128
id
horizontal
RT 138 (1)
id
swing out
RT 143
id
swing out
RT 150
id
swing out
RT 151 (3)
id
angel fixed 45º
RT 152 (3)
id
angel fixed 30º
RT 153 (3)
id
angel fixed 30º
RT 154 (3)
id
angel fixed 28º
RT 183
id
angel fixed
18x15 ml.24x15 ml.24x5 ml.6x50 ml.24 de 1,5x75ml.4x100 ml.4x50 ml.2,4,6 Microtiter24 de 1,5-2 ml.12x10ml Hermét8x30 ml Hermét6x50 ml Hermét32 de 0,2 ml.
420042006500600013000500053004000165001500013500900014000
132132/1141131328614514512282789210158
26032603/22485338531316249405345542182249591962118746914612700
0-1111-4-4024412
TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF TUBESREF
-- -- -- -- -- 4- -- -- -- -- -- -- --
-- -- -- -- -- 4RE 380 -- -- -- -- -- -- --
-- -- -- -- -- 4RE 338 -- -- -- -- -- -- --
-- -- -- 6RE 386 -- 4RE 381 4RE 378 -- -- -- -- 6- --
-- -- -- 6- -- 4RE 335 4- -- -- -- -- -- --
-- -- -- -- -- -- -- -- -- -- -- 6- --
-- -- -- 6RE 387 -- 4RE 382 4RE 379 -- -- -- 8- 6RE 392 --
-- -- -- 6RE 362 -- 4RE 332 4RE 333 -- -- -- 8- 6RE 393 --
18- 24- -- 6RE 361 -- 16RE 316 4RE 329 -- -- -- 8RE 406 6RE 394 --
18- 12- -- 6RE 361 -- 4RE 339 4RE 329 -- -- -- -- 6RE394(2) --
18- 24- -- 6RE 361 -- 16RE 316 4RE 329 -- -- -- -- 6RE 394 --
18RE 383 24RE 384 -- 6RE 361 -- 16RE 316 4RE 342 -- -- 12- 8RE 319 6RE 395 --
18RE 359 24RE 385 -- 6RE 360 -- 20RE 320 12RE 313 -- -- -- 8RE 407 6RE 396 --
18RE 359 24RE 385 -- 6RE 364 -- 20RE 320 4RE 337 -- -- -- -- 6RE 396 --
18RE 303 24RE 306 24- 6RE 360 -- 20RE 320 4RE 337 -- -- 12RE 389 8RE 390 6RE 397 --
18RE 303 24RE 306 24- 6RE 360 -- 20RE 320 12RE 313 -- -- 12RE 389 8RE 390 6RE 397 --
-- -- -- -- 24- -- -- -- -- -- -- -- --
-- -- -- -- -- 20RE 408 -- 72RE 401 24- -- -- 18RE 433 --
-- -- -- -- -- -- -- -- 24RE 305 -- -- -- --
-- -- -- -- -- -- -- -- 24RE 304 -- -- -- 32x02ml.-
-- -- -- -- -- -- -- 6- -- -- -- -- --
-- -- -- -- -- -- -- 4- -- -- -- -- --
-- -- -- -- -- -- -- 2- -- -- -- -- --
-- -- -- -- -- -- -- 4- -- -- -- -- --
(1) This rotor includes hermetic lids
(2) Fitting this tubes rotor lid can not be closed.
(3) Check tubes features