Digicen 21R

The centrifuge refrigerated Digicen 21R can reach up to 24.959 xg with a wide range of rotors:

  • Swing out rotors, with a max volume of 4 x 100 ml which can fit several set of adapters
    for tubes with or without caps, microtubes, microplates.
  • Angle fixed low speed for routine purposes.
  • Angle fixed high speed from microtubes to 50 ml conical tubes.

On LCD screen shown the selectable values as time, RPM, RCF, temperature and braking time as well as graphics for lid open, progress bar, and acoustic signals for a better control about the process by operator.

The powerful refrigeration system, enhanced by the pre-cooling program, keep the samples at stable and controlled temperature, avoiding sample´s temperature fluctuations at introducing into the device.

Stabilizing sample preparation.

 

User friendliness

  • LCD screen shown RPM/RCF (on steps 100 RPM/10xg),time, temperature (1°C steps) and acceleration/deceleration (1 second steps).
  • Intuitive handling through start, stop, short spin and lid keys.
  • Rotor list on memory.
  • Timer count up/down, from 0 or at “set RPM/RCF” for test reproducibility.
  • Short spin key with speed adjustable.
  • Automatic rotor recognition.
  • Acceleration and braking selectable by operator.
  • 15 memories and pre-cooling program.
  • Lid latch lock.
  • Microprocessor controlled.
  • Option: free or locked adjustment of RPM/RCF along the run.

Features

  • Induction motor maintenance free
  • Max. capacity 4 x 100 ml.
  • Speed, up to 24.959 xg/16.500 RPM.
  • Quiet: noise level < 60 dB.

Safety

  • Lid locking and holding.
  • Imbalance switch off.
  • Manual overriding.
  • Chamber of centrifugation in stainless steel.
  • Viewing and calibration port in the lid.
  • Several messages keep the operator informed about the device situation.
  • Guard ring between the chamber of centrifugation and the housing.
  • Lid dropping protection.

Cooling

  • Precooling program with rotor spinning and temperature selectable by operator.
  • 4°C at Max speed as higher.
  • Temperature range -20°C (-4 °F) to 40°C (104 °F)
  • Temperature sensor inside the chamber, gas R 404A HFC.

Standards and EC Directives

EU Directives: 98/79/EC, 2006/95/EC, 2004/108/EC, 2011/65/EU, 2012/19/EU.
Regulation: 1005/2009 & 842/2006.
Standards: EN 61010-1, EN 61010-2-020, EN 61326-1.

 

Versions

Code Dimensions (mm)(w x d x h) Net weight (Kg) Voltage
(V)
Frecuency
(Hz)
Consumption
(W)
Z max Advisable(Hz)
CE 113 590 680 320 67 220-240 50-60 700 <|0.446|
CE 119 590 680 320 67 110-120 50-60 700 <|0.446|

accesorios

  RT 143
id
RT 138 (1)
id
RT 150
id
RT 183
id
RT 128
id
  + info + info + info + info + info
ROTOR SWING OUT SWING OUT SWING OUT ANGLE FIXED HORIZONTAL
Max. capacity 4 x 50 ml. 4 x 100 ml. 2,4 o 6 Microtiter 32 of 0,2 ml. 24 of 1,5 x 75 ml.
RPM 5300 5000 4000 16500 13000
Radius(mm) 145 147 122 (4) 55 (4) 87
RCF Max. (xg) 4554 4019 2182 16741 16438
Min. temp. max speed (°C) -4 -4 0 2 1
  RT 151 (3)
id
RT 110
id
RT 106
id
RT 108
id
RT 121 (3)
id
  + info + info + info + info + info
ROTOR ANGLE FIXED 45º ANGLE FIXED 35º ANGLE FIXED 35º ANGLE FIXED 35º ANGLE FIXED 45º
Max. capacity 24 of 1,5-2 ml. 24 x 5 ml. 18 x 15 ml. 24 x 15 ml. 6 x 50 ml.
RPM 16500 6500 5000 5000 6000
Radius(mm) 82 113 132 132/114 132
RCF Max. (xg) 24959 5338 3689 3689/3186 5313
Min. temp. max speed (°C) 2 1 0 -1 1
  RT 152 (3)
id
RT 153 (3)
id
RT 154 (3)
id
RT 253
id
id
  + info + info + info + info
ROTOR ANGLE FIXED 30º ANGLE FIXED 30º ANGLE FIXED 28º ANGLE FIXED 45º
Max. capacity 12 x 10 ml Hermét 8 x 30 ml Hermét 6 x 50 ml Hermét 12 x 5 ml
RPM 15000 13500 9000 16500
Radius(mm) 78 92 101 87
RCF Max. (xg) 19621 18746 9146 26480
Min. temp. max speed (°C) 4 4 1 5

(1) This rotor includes hermetic lids.
(2) Fitting this tubes rotor lid can not be closed.
(3) Please, check tubes feature.
(4) Medium radio on bucket.